Difference: HybridOne (6 vs. 7)

Revision 72017-03-03 - TomErikHaugen

Line: 1 to 1
 
META TOPICPARENT name="FirstElectricalHybridPanel"

Hybrid One (First Electrical Panel)

Line: 25 to 25
  HCC ID and ABC ID (on chip ID 20) were incorrectly bonded, both had all four ID's bonded (corresponding to ID 16). Co was able to remove single bond on each (ID2) to get correct ID (Feb 27th).
Changed:
<
<

DAQ

>
>

DAQ Results

  Once incorrect ID bonds were removed we were able to connect to hybrid. Results from scan are included below (scans were run on March 3rd). Tests were run on both hybrid 1 and 7 at same time.
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.