First Electrical Module (ABC130)

This module was constructed with hybrid one and hybrid seven.

Construction

Hybrid seven was mounted on May 4th. On May 8th we attempted to mount hybrid one, however we saw that chip 3 had come loose. That chip was replaced, bonded, tested, and then the hybrid was mounted onto the module.

Hybrid seven was bonded to the module on May 10th. While bonding hybrid one on May 12th we found all of the chips on the HCC side were loose. The bonder broke the small amount of glue connection on chips 0-5 (chip 3 had already been replaced).

Metrology was performed using the SmartScope on both hybrids on the sensor. Using 2 points on the corners of the chips and one point on the hybrid between each chip. Fitting the hybrid heights with a polynomial and subtracting that fit from the chip heights we see the following measurements (this was when only one chip had been replaced):

Module_Metrology_Replaced_Chip.png

The goal for the glue heights is 80 microns. Each glue dot is originally made at 120 microns then squeezed down to 80. This shows hybrid seven was glued well, but that hybrid 1 had some absolute slope that caused the chips on one side to not be pressed down enough. Therefore there was only a small amount of glue contact and that broke over time in handling the hybrid.

Chips 0-5 were all replaced (again chip 3 had been replaced before mounting the hybrid). The chips were bonded to the hybrid and the hybrid was bonded to the test frame. This was so that we could test the hybrid before and after bonding to the module.

Retesting Hybrid 1

The first attempts to connect resulted in not being able to capture the HCC ID. After debugging some we found (with the help of Karol) that the data lines were inverted relative to the DAQload, resulting in the binary signal being inverted. This is shown in the image below

Data_Lines.png

After flipping the wire bonds we were able to run all of the tests and get results.

If you keep the wire bonds as written in Liverpool's wire bonding diagram, you can use variable 53 in ITSDAQ to do the data inversion.

[e->ConfigureVariable(X, 53, Y)] where X is the module number from the configuration file (first number in the system config line) and Y = 0/1 (0 for normal, and 1 for invert. *This was implemented in ATLYS a116 or later and NEXYS b118 or later.

Results:

HV Biasing

The original plan was to follow the wire bond diagram for module construction. After talking with Craig it became clear that we should vary the plan some. To correctly connect the HV we had to do the following steps:

  • Solder a wire on the test frame to short HVret and LV GND
  • Connect the four corners with AC connections, then connect one of the inner corners of the hybrid to the bias ring to route the leakage current into the HCC
  • Not connect the HVret on the hybrid to the frame, as R2 creates a lot of noise for the system.
Module_Data_Bonds.jpg Module_Power_Bonds.jpg

Electrical_Module_7_26_2017_2_Wire.JPG

Power Board

Rhonda glued the power board by hand with 24hr Epolite 5313A epoxy and fishing wire. When the power board was first placed, there wasn't enough glue. It was then picked up by the shield box, and glue was added to the bottom of the power board. To hold it in place, a foam and plexiglass piece was improvised, and a weight was put on top of it. In hindsight, we should have used the usual brass weight instead of the one pictured. When gluing the power board, we had to be careful not to get glue on the guard ring, as that is known to cause early break down of the sensor.

GluingPB_during.JPG

Adding extra glue to the power board.

GluingPB_topview.JPG

Foam and plexiglass piece created to hold down power board.

GluingPB_weight.JPG

Gluing power board with weight. (Next time, should use brass weight.)

GR_check.JPG

Checking for glue on the guard ring.

Electrical_Module_wPB.JPG

Completed EL-01.

-- Charilou Labitan - 2018-02-01

Comments


Topic attachments
I Attachment History Action Size Date Who Comment
PNGpng ABC130_Module_Connection.png r1 manage 2227.4 K 2017-07-21 - 06:34 TomErikHaugen  
PNGpng Data_Lines.png r1 manage 1933.5 K 2017-06-26 - 17:03 TomErikHaugen  
JPEGJPG Electrical_Module_7_26_2017_2_Wire.JPG r2 r1 manage 324.4 K 2018-01-17 - 18:43 CharilouLabitan LVGND_HVret_Connection
JPEGJPG Electrical_Module_wPB.JPG r1 manage 2660.3 K 2018-02-01 - 21:04 CharilouLabitan LBL EL-01 (Complete with Power Board)
JPEGJPG GR_check.JPG r1 manage 2458.9 K 2018-01-17 - 19:12 CharilouLabitan No glue on guard ring
JPEGJPG GluingPB_during.JPG r1 manage 1613.5 K 2018-01-17 - 19:11 CharilouLabitan Adding extra glue
JPEGJPG GluingPB_sideview.JPG r1 manage 1555.9 K 2018-01-17 - 19:11 CharilouLabitan Gluing PB before weight
JPEGJPG GluingPB_topview.JPG r1 manage 2291.8 K 2018-01-17 - 19:12 CharilouLabitan Gluing PB before weight
JPEGJPG GluingPB_weight.JPG r1 manage 1890.8 K 2018-01-17 - 19:18 CharilouLabitan Curing the PB with the weight
JPEGjpg IMG_20170615_184126927_1.jpg r1 manage 306.3 K 2017-06-26 - 16:59 TomErikHaugen  
JPEGjpg IMG_20170615_184207176_1.jpg r1 manage 307.6 K 2017-06-26 - 16:59 TomErikHaugen  
JPEGjpg Module_Data_Bonds.jpg r1 manage 565.5 K 2017-07-21 - 06:34 TomErikHaugen  
PNGpng Module_Metrology_Replaced_Chip.png r1 manage 72.2 K 2017-06-26 - 17:14 TomErikHaugen  
JPEGjpg Module_Power_Bonds.jpg r1 manage 507.4 K 2017-07-21 - 06:34 TomErikHaugen  

This topic: Strips > WebHome > FirstElectricalHybridPanel > ElectricalPrototypeHybridSeven > FirstElectricalModule
Topic revision: r8 - 2018-02-01 - CharilouLabitan
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback